23 research outputs found

    Making MRI available for patients with cardiac implantable electronic devices: growing need and barriers to change

    Get PDF
    More than half of us will need a magnetic resonance imaging (MRI) scan in our lifetimes. MRI is an unmatched diagnostic test for an expanding range of indications including neurological and musculoskeletal disorders, cancer diagnosis, and treatment planning. Unfortunately, patients with cardiac pacemakers or defibrillators have historically been prevented from having MRI because of safety concerns. This results in delayed diagnoses, more invasive investigations, and increased cost. Major developments have addressed this-newer devices are designed to be safe in MRI machines under specific conditions, and older legacy devices can be scanned provided strict protocols are followed. This service however remains difficult to deliver sustainably worldwide: MRI provision remains grossly inadequate because patients are less likely to be referred, and face difficulties accessing services even when referred. Barriers still exist but are no longer technical. These include logistical hurdles (poor cardiology and radiology interaction at physician and technician levels), financial incentives (re-imbursement is either absent or fails to acknowledge the complexity), and education (physicians self-censor MRI requests). This article therefore highlights the recent changes in the clinical, logistical, and regulatory landscape. The aim of the article is to enable and encourage healthcare providers and local champions to build MRI services urgently for cardiac device patients, so that they may benefit from the same access to MRI as everyone else. KEY POINTS: • There is now considerable evidence that MRI can be provided safely to patients with cardiac implantable electronic devices (CIEDs). However, the volume of MRI scans delivered to patients with CIEDs is fifty times lower than that of the estimated need, and patients are approximately fifty times less likely to be referred. • Because scans for this patient group are frequently for cancer diagnosis and treatment planning, MRI services need to develop rapidly, but the barriers are no longer technical. • New services face logistical, educational, and financial hurdles which can be addressed effectively to establish a sustainable service at scale

    Evidence to support magnetic resonance conditional labelling of all pacemaker and defibrillator leads in patients with cardiac implantable electronic devices

    Get PDF
    Aims: Many cardiac pacemakers and defibrillators are not approved by regulators for magnetic resonance imaging (MRI). Even following generator exchange to an approved magnetic resonance (MR)-conditional model, many systems remain classified ‘non-MR conditional’ due to the leads. This classification makes patient access to MRI challenging, but there is no evidence of increased clinical risk. We compared the effect of MRI on non-MR conditional and MR-conditional pacemaker and defibrillator leads. // Methods and results: Patients undergoing clinical 1.5T MRI with pacemakers and defibrillators in three centres over 5 years were included. Magnetic resonance imaging protocols were similar for MR-conditional and non-MR conditional systems. Devices were interrogated pre- and immediately post-scan, and at follow-up, and adverse clinical events recorded. Lead parameter changes peri-scan were stratified by MR-conditional labelling. A total of 1148 MRI examinations were performed in 970 patients (54% non-MR conditional systems, 39% defibrillators, 15% pacing-dependent) with 2268 leads. There were no lead-related adverse clinical events, and no clinically significant immediate or late lead parameter changes following MRI in either MR-conditional or non-MR conditional leads. Small reductions in atrial and right ventricular sensed amplitudes and impedances were similar between groups, with no difference in the proportion of leads with parameter changes greater than pre-defined thresholds (7.1%, 95% confidence interval: 6.1–8.3). // Conclusions: There was no increased risk of MRI in patients with non-MR conditional pacemaker or defibrillator leads when following recommended protocols. Standardizing MR conditions for all leads would significantly improve access to MRI by enabling patients to be scanned in non-specialist centres, with no discernible incremental risk

    The interplay of structure and reactivity in a most unusual furan diels-alder reaction

    No full text
    Difluorinated alkenoate ethyl 3,3-difluoro-2-(N,N-diethylcarbamoyloxy)-2-propenoate reacts rapidly and in high yield with furan and a range of substituted furans in the presence of a tin(IV) catalyst. Non-fluorinated congener 2-(N,N-diethylcarbamoyloxy)-2-propenoate fails to react at all under the same conditions. These reactions have been explored using density functional theory (DFT) calculations. They reveal a highly polar transition state, which is stabilized by the Lewis acid catalyst SnCl4 and by polar solvents. In the presence of both catalyst and solvent, a two-step reaction is predicted, corresponding to the stepwise formation of the two new carbon−carbon bonds via transition states which have similar energies in all cases. Our experimental observations of the lack of reaction of the non-fluorinated dienophile, the stereochemical outcomes, and the rate acceleration accompanying furan methylation are all well predicted by our calculations. The calculated free energy barriers generally correlate well with measured reaction rates, supporting a reaction mechanism in which zwitterionic character is developed strongly. An in situ ring opening reaction of exo-cycloadduct ethyl exo-2-(N,N-diethylcarbamoyloxy)-3,3-difluoro-7-oxabicyclo[2.2.1]hept-5-enyl-2-endo-carboxylate, which results in the formation of cyclic carbonate ethyl 4,4-difluoro-5-hydroxy-2-oxo-5,7a-dihydro-4H-benzo[1,3]dioxole-3a-carboxylate by a Curtin−Hammett mechanism, has also been examined. Substantial steric opposition to Lewis acid binding prevents carbonate formation from 2-substituted furans

    The retirement behaviour of the self-employed in Britain

    No full text
    We analyze the retirement behaviour of older self-employed workers, using a life cycle framework and a multinomial logit model of dynamic employment and retirement choices. Using data from the two-wave Retirement Survey, we find that greater actual or potential earnings decrease the probability of retirement among the self-employed. In contrast to employees, none of gender, health or family circumstances appear to affect self-employed retirement decisions. The dynamic analysis reveals that relatively few employees and virtually no retirees switch into self-employment in later life. The switches that do occur are motivated less by attempts to use self-employment as a bridge job or 'stepping stone' to full retirement, than by self-employment being a last resort for less affluent workers with job histories of weak attachment to the labour market. We compare self-employed and employee retirement behaviour and discuss the policy implications of our results.

    The effect of the workplace on motivation and demotivation of construction professionals

    No full text
    Investigations have been carried out which suggest that motivation of employees in all industries is affected by the environment or culture in which they work. Research undertaken in Melbourne, Australia investigated the effect of the workplace environment encountered on a construction site on motivation and demotivation of construction professionals. The data collected supported the hypothesis that the environment of a construction site does affect demotivation levels of site personnel. Specifically, several variables were significantly linked to this result, including long hours, chaos, non-recognition for work done and colleagues' aggressive management style. The results provide a valuable basis for indicating how the construction industry can create a more attractive workplace environment for professional site staff.Culture Motivation Demotivation Management Workplace,
    corecore